CCP4bb navigationCCP4bb <-- 2008 <-- January 2008 <-- 03 January 2008Subject: resolution & R-free From: 杨柳青 yangliuqing1984 {- at -} HOTMAIL {- dot -} COM Date: 2008-01-03 Hi,dear all: I try to refine one protein structure using refmac5,now I got some problems. For example,first,the resolution is 2.25,R-free is 30,completeness is 90%. Then I changed resolution to 2.35,R-free became 28.0,completeness is 91%. When I changed resolution to 2.45,R-free became 27.5,completeness is 92%. So,when resolution from 2.25 to 2.35,R-free goes down a lot,but resolution from 2.35 to 2.45,R-free nearly the same,is that meaning resolution should around 2.35? Should I change resolution during refinement? And is there any good software for refinement? Thanks a lot! Best wishes! liuqing _________________________________________________________________ 天凉了,添衣了,心动了,“七件”了 http://get.live.cn CCP4bb navigationCCP4bb <-- 2008 <-- January 2008 <-- 03 January 2008 |