| Quick navigation: | Home | Site Map || References | Biography || Copyright | Other copyright | Contact us | | |
|
Re: [ccp4bb] XDS - resolution limit |
|
CCP4bb navigationCCP4bb <-- 2008 <-- February 2008 <-- 18 February 2008Subject: Re: XDS - resolution limit From: Kay Diederichs Kay {- dot -} Diederichs {- at -} UNI-KONSTANZ {- dot -} DE Date: 2008-02-18 the keyword is TRUSTED_REGION (see http://www.mpimf-heidelberg.mpg.de/~kabsch/xds/html_doc/xds_parameters.html#TRUSTED_REGION= and http://strucbio.biologie.uni-konstanz.de/xdswiki/index.php/XDS.INP in XDSwiki). HTH, Kay Florian Schmitzberger schrieb: > Dear All, > > Is there a way to get XDS to include reflections in the far corners of > diffraction images. > > XDS seems to take the high-resolution limit automatically from the edge > of the images corresponding to the smallest radius from the center. In > my case, with the keyword set to "INCLUDE_RESOLUTION_RANGE=50 0.0" it > does not appear to include all reflections (those higher than 1.80 A > resolution), although there are reflections to 1.60 A resolution in the > corner of the diffraction images. I would like to include these > reflections in the integration and processing. (Diffraction data was > collected on a ADSC Quantum Q315r detector). > > Maybe I am missing something obvious. > > Thank you very much for any comments. > > Florian -- Kay Diederichs http://strucbio.biologie.uni-konstanz.de email: Kay.Diederichs@uni-konstanz.de Tel +49 7531 88 4049 Fax 3183 Fachbereich Biologie, Universität Konstanz, Box M647, D-78457 Konstanz CCP4bb navigationCCP4bb <-- 2008 <-- February 2008 <-- 18 February 2008 |
| ProteinCrystallography.org: Copyright 2006-2007 by Quid United Ltd |